- Non-contact tracing of the transmission signal by the receiver
- Fast tracing of coherent electrical circuits
- Location of lines in coherent, live electrical circuits
- Detection of fuse circuits in live installations
- Receiver with audible signal tone for locating measured objects
- Transmitter power supply directly from power cable to be tested = measurement under operating conditions
- Receiver with adjustable sensitivity for optimum fine adjustment
- Socket adapter for direct and fast testing in building installations
- E27 lamp adapter for direct and fast testing in lamp circuits
Technical data
| TRANSMITTER AC-TRACER TX | |
| POWER SUPPLY | 200-240V AC, 50-60 Hz |
| OVERVOLTAGE CATEGORY | CAT III 300V, pollution degree 2 |
| DIMENSIONS (W x H x D) | 50 x 80 x 32 mm |
| WEIGHT | 54 g |
| RECEIVER AC-TRACER RECV | |
| MEASURING RANGE | 0…5 cm measuring depth |
| POWER SUPPLY | 1 x 9V block, IEC LR6, Alkali |
| DIMENSIONS (W x H x D) | 68 x 165 x 36 mm |
| WEIGHT | (incl. battery) 155 g |